Abstract

Abstract: Level of Noise in the residential around muara teweh’s PLTD. Muara Teweh’s PLTD was one of the regional companied responsible for the provision of electricity serviced. The impact of the operation of the PLTD is the emergence of noise caused by the PLTD engine so that it appeared on public complainted, especially communication disordered, disordered of physiological and psychological disordered. This study aims to determine the noise level and subjective complainted felt in residential areas around Muara Teweh’s PLTD. This research was a descriptive observational describe the noise level in residential areas Muara Teweh’s PLTD. This study include cross-sectional design that aims to determine the noise until at residential areas around Muara Teweh’s PLTD and connect with public complainted in residential areas around Muara Teweh’s PLTD. The measurement resulted show noise levels in residential areas around Muara Teweh’s PLTD exceeded the NAV according KEPMEN / LH / 48/1996, which is 62.9 dBA in the North, 70.4 dBA in the Northeast, 69.3 dBA in the East , 69.4 dBA in the direction of the Southeast, 72.3 dBA in the south, 72.2 dBA in the direction of the Southwest, 78.2 in the West and 75.5 dBA in the northwest. Subjective complainted of the most widely felt in residential areas Muara Teweh’s PLTD form (45.9%), headache (56.8%), discomfort (91.9%), insomnia (83.8%) fast and emotions (40.5%). Efforts should be madeto controlnoise levelsand complaintsaregiving them the toolsnoise suppressioninengine room, thickenthe barrier, put upcurtainsat thewindows of the houseanddo notoftenopen thedoor. Keywords         :           Noisy environment, residential noise

Article Details

Section
Articles

References

Rahayu, Titiek. 2010. Dampak Kebisingan Terhadap Munculnya Ganggusn Kesehatan.

Banitriono, Rendika. 2012.Hubungan Antara Kemampuan Pendengaran dan Radius Rumah Pada Warga Masyarakat di Sekitar PLTD Siantan Hilir.Fakultas Kedokteran Universitas Tanjungpura, Pontianak

PLTD Muara Teweh, PT.PLN (Persero) Kuala Kapuas. 2012.Laporan Upaya Pemantauan Lingkungan (UPL) PLTD Muara Teweh.

Buchari.2007. Kebisingan Industri dan Hearing Conservation. Universitas Sumatera Utara, Medan.

Djalante, S.2010. Analisis Tingkat Kebisingan di Jalan raya yang Menggunakan Alat Pembiri Isyarat Lalu Lintas (APIL) (Studi Kasus : Simpang Ade Swalayan). Jurnal SMARTek.

Satwiko, P. 2005.Fisika Bangunan 1 (edisi 2).Andi, Yogyakarta.

Nugroho, Slamet.2003. Formulir Survey Dampak Kebisingan. Direktorat PPM & PL, Depkes, Jakarta.

Prasetio, L.1985. Akustik Lingkungan. Erlangga, Jakarta .

Sears, M. Zeamansky dan F. W.1999. Fisika untuk Universitas 1 (Mekanika, Panas dan Bunyi). Trimitra Mandiri, Jakarta .

MenLH.Baku Kebisingan. Surat Keputusan Menteri Lingkungan Hidup Nomor: Kep-48/MENLH/1996/25. Jakarta : MenLH, 1996.