Kadar Sisa Klor Terhadap Nilai MPN Coliform Pada Jaringan Perpipaan PDAM Di Kabupaten Hulu Sungai Utara

Main Article Content

Muhammad Rifani
Munawar Raharja
Isnawati Isnawati

Abstract

Abstract :   Study of free chlorine levels with a value of MPN coliform in water piping distribution PDAM Kabupaten Hulu Sungai Utara Year 2016. Provision of safe drinking water must also meet quality requirements which include requirements physical,  chemical,  bacteriological  and  radiological.  River  water  one  source  of  raw water for water companies. Perusahaan Daerah Air Minum (PDAM) Kabupaten Hulu Sungai Utara is a provider of clean water. Based on secondary data report PDAM to maintain water quality after processing up to the distribution network PDAM using chlorine   disinfection   materials.   The   purpose   of   this   study   was   to   analyze   the relationship between the value of the levels of residual chlorine by MPN coliform in the water pipeline distribution network PDAM. This type of research is observational analytic with cross sectional study design. The samples used were water PDAM Kabupaten Hulu Sungai Utara in the distribution network at a distance of 0, 2, 4, and 6 km from the reservoir. The results showed that decreased levels of free chlorine from distance making 0, 2, 4 and 6 km between 1.5 to 0.0 mg / L.  Test results showed coliform  MPN  value  is  0  /  100mL.    After  testing  regression  analysis  the  effect  of distance on the maximum levels of residual chlorine with R = 0.834 (strong) and regression analysis test the effect of distance to the minimum levels of residual chlorine with  R  =  0.943  (strong).  To  test  the  statistical  relationship  between  the  levels  of residual chlorine with coliform MPN value was not done because the results of the coliform MPN no difference. All parameters examined in this study meet the requirements under Permenkes No. 492 / Menkes / PER / VI / 2010. Efforts to do is do a jar test dose in increments of water disinfection, to supervise the treatment system and the distribution network piping. Keywords: PDAM water, distance distribution networks, free chlorine, MPN coliform

Article Details

Section
Articles

References

Chandra B. 2007. Pengantar Kesehatan Lingkungan. Buku Kedokteran EGC. Jakarta

Asmadi, Khayan, Kasjono, H. 2011. Teknologi Pengolahan Air Minum. Gosyen Publishing. Yogyakarta

Sutrisno. 2002. Teknologi Penyediaan Air Bersih. Rineka Cipta. Jakarta

PDAM Kabupaten Hulu Sungai Utara. 2015 Laporan Harian Pemeriksaan Kadar Sisa Klor Bulan September 2015

Sumantri 2010. Kesehatan Lingkungan. Kencana Prenada Media Group. Jakarta

Alaerts G, Santika Sri S. 1987. Metoda penelitian air. Usaha Nasional. Surabaya

Laporan Hasil Uji Laboratorium Kesehatan Banjarmasin Bulan September 2015

Permenkes No. 492/MENKES/PER/IV/2010 tentang Persyaratan Kualitas Air Minum